EWA Release 40.2.12
Version 40.2.12 stable: Component Versions
Version 40.2.12 stable of EWA was released to customers on June 06th 2026.
The compatible versions of the affected runtime components are listed below:
| Component | Version |
|---|---|
| Insights API | 26.6.102.0 |
Version 40.2.12 stable: New Features
No new features were included in this release.
Version 40.2.12 stable: Updated Features
No updated features were included in this release.
Version 40.2.12 stable: Fixes
Unable to create or modify LiveView configuration from Insight.
- Ticket: 419221867731
- DevOps: 39566
- Reported by: HSØ
- HubSpot Title: EWA 40.2.11 - Ikke mulig å opprette nye eller gjøre endringer på eksisterende Sanntidsskjermer
- Internal Reference: PT-180
-
Issue: Creating or modifying LiveView configuration from Insights results in a 500 error, and the configuration is not saved.
-
Solution:
- The on‑prem InsightsAPI-CI pipeline used sparse checkout and unintentionally excluded the repository’s global.json. As a result, the .NET SDK was not pinned, and builds defaulted to the highest available SDK on the agent (e.g., .NET 10 / C# 14). This caused incompatible LINQ translation behavior in EF6 at runtime.The Fix is by updating the pipeline to include /global.json in the sparse checkout configuration. This ensures the build uses the intended .NET 8 SDK (via SDK pinning and roll-forward policy), restoring compatibility and preventing the runtime failure.
-
Affected components: Insights API
✅ Affected components
Compiled a list of affected components impacted by the fixes included in version 40.2.12.
- Insights API
For release 40.2.12 release we recommend to install Insights API
✅ Testing Focus Areas for 40.2.12 Fixes
🧾 LiveView Configuration
-
Validate creating and updating LiveView (Sanntidsvisning) configurations from Insights works without errors
-
Verify no 500 error response is returned during create/update operations
-
Ensure configurations are successfully saved and persisted
Tested Medical Devices
All versions of this release have been tested on the listed medical devices and corresponding software versions, ensuring compatibility and performance in the specified environments.
Corpuls
- Software versions: 4.4.4
- SDK version: 4.4.0.0
Zoll
- Software version: 02.36.21.00
- SDK version: 6.44.315